Imaging Performance
Resolution - 640x480
Detector Type - VOx Microbolometer
Sensitivity - 50 mK (0.05°C)
Field of View - Min. Focus 25°x18° / 0.4 m
Frame Fate -30 Hz – Models HD-B, HD-BE
9 Hz – Model HD-BE9
Focus - Manual
Visible Camera - 1280x1024 pixels, flash, torch
Image Presentation
Image Modes - IR/PIP/Fusion
Display - 3.5" 640x480 LCD touchscreen
Color Palettes - 7 (4 color, 3 grey)
Measurement
Temperature Range -20°C to 350°C
Accuracy ±2°C or ±2% (whichever is greater)
Spot Size Ratio -500:1 (standard lens)
Measurement Modes - Point (5), Line, Area (user defi ned)
Measurement Correction - emissivity, background/transmission/ ambient
Image Storage and Camera Functionality
Digital Media - 512MB CF card (~600 hi-res images)
Internal Image Capacity - 512MB (~600 hi-res images)
Recording Modes - Snapshot/sequence (optional)
Image Annotation - Touchscreen data logger GUI
In-Camera - Routing Included
Target Marker - Dual laser line target identifi er
Classification - Class 2
Power
Battery Type - Rechargeable Lithum-Ion
Battery Run Time - 2.5 hours
Battery Charging - 10-16VDC input. Charging status LED
AC Power Supply - 100-270 VAC, 50/60 Hz
Environmental
Operating Temp. Range -5°C to 50°C
Storage Temperature Range -30°C to 70°C
Humidity 10% to 95%, IEC 360
Water and Dust - IP-54
Shock /Vibration - 25G, IEC 68-2-29 / 2G, IEC 68-2-6
Physical
Weight - 2.7 lbs.
Dimensions - (WxHxD) 7.5" x 7.5" x 3"
Interfaces
Image Transfer - USB 2.0, CF card
Real-time Digital Output - USB 2.0 Model HD-S only
Analog Video - NTSC Model HD-S only
Desktop Software
ViewIR™ - Included
ReportIR™ - Automatic multi-page report (optional)
RouteIR™ - Thermography program management software package (optional)
Fault Tree Manager™ -Equipment-type editor (optional)